Abstract:
In this paper, the change of work function ( Δφ ) of the tellurium thin films was studied in response to different concentrations of nitrogen dioxide, carbon oxide, ozone and water vapor using a KP with a gold grid reference electrode. In all experiments, the relative change of work function was determined at room temperature.
Description: