IRTUM – Institutional Repository of the Technical University of Moldova

Steady State Condition of Cable Line 10 kV at Single-Phase to Ground Fault with Resistive Neutral Earthing

Show simple item record

dc.contributor.author BOŞNEAGĂ, Valeriu
dc.contributor.author SUSLOV, Victor
dc.contributor.author STRATAN, Ion
dc.contributor.author DOBREA, Ina
dc.date.accessioned 2023-11-24T12:46:41Z
dc.date.available 2023-11-24T12:46:41Z
dc.date.issued 2023
dc.identifier.citation BOŞNEAGĂ, Valeriu... DOBREA, Ina et al. Steady State Condition of Cable Line 10 kV at Single-Phase to Ground Fault with Resistive Neutral Earthing. In: International Conference on Electromechanical and Energy Systems: proc. SIELMEN-2023, 11-13 Oct. 2023. Craiova, Romania, 2023, pp. 1-6. e-ISBN 979-8-3503-1524-0. en_US
dc.identifier.isbn 979-8-3503-1524-0
dc.identifier.uri https://doi.org/10.1109/SIELMEN59038.2023.10290827
dc.identifier.uri http://repository.utm.md/handle/5014/25010
dc.description Acces full text - https://doi.org/10.1109/SIELMEN59038.2023.10290827 en_US
dc.description.abstract The work is devoted to the study of the steady state mode of cable line 10 kV at single-phase short circuit and resistive grounding of the neutral. A model of a cable line, implemented in the MATLAB-SIMULINK package was used. Also the models of supply transformer and additional transformer for creation of artificial neutral point were used, based on available standard elements. So, the specifics of operation of additional transformer for creation an artificial neutral point and real parameters of the cable and transformers were taken into account. It is shown that in the resistive grounding mode the nature of the displacement of the linear supply voltages triangle at variation of the fault resistance differs from what takes place in the partial compensation and overcompensation modes. At single-phase short circuit and any value of fault resistance, the choice of the value of the resistor in the neutral significantly affect the magnitude of the current and voltage in it. However, the current and the voltage at the place of damage at large values of the fault resistance does not significantly depend on the value of the neutral resistor. en_US
dc.language.iso en en_US
dc.publisher Institute of Electrical and Electronics Engineers, IEEE en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject cable distribution lines en_US
dc.subject steady state modes en_US
dc.subject single-phase failures en_US
dc.subject resistive grounding of the neutral en_US
dc.title Steady State Condition of Cable Line 10 kV at Single-Phase to Ground Fault with Resistive Neutral Earthing en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account