IRTUM – Institutional Repository of the Technical University of Moldova

Comparative analysis of cryopreserved ram sperm parameters depending on the dilution medium

Show simple item record

dc.contributor.author DARIE, Grigore
dc.contributor.author CIBOTARU, Elena
dc.contributor.author DJENJERA, Irina
dc.contributor.author BRADU, Nina
dc.date.accessioned 2026-06-22T08:57:28Z
dc.date.available 2026-06-22T08:57:28Z
dc.date.issued 2025
dc.identifier.citation DARIE, Grigore; Elena CIBOTARU; Irina DJENJERA and Nina BRADU. Comparative analysis of cryopreserved ram sperm parameters depending on the dilution medium = Сравнителен анализ на параметрите на криоконсервирана сперма от коч в зависимост от използваната среда. Journal of Mountain Agriculture on the Balkans. 2025, vol. 28, no. 4, pp.14-32. ISSN 1311-0489 en_US
dc.identifier.issn 1311-0489
dc.identifier.issn 2367-8364
dc.identifier.uri https://repository.utm.md/handle/5014/36516
dc.description.abstract To improve the effectiveness of long-term sperm storage outside the animal’s body, it is necessary to enhance the protective media that help reduce the impact of cryodamaging factors on sperm. In this study, sperm from Assaf breed rams was used. Sperm was collected from the rams twice a week using an artificial vagina, which ensured high-quality material. For analysis, ejaculates with at least 70% motility and a concentration of 2,0 to 2,5 billion sperm per milliliter were selected. The aim of the study was to compare the parameters of cryopreserved sperm depending on the synthetic media used: GTJ, STJ+MP, and STJ+IMB-2. This allowed for the determination of the most suitable extender to ensure a higher fertilization rate. During the study, the main parameters of cryopreserved sperm were analyzed, including motility, percentage of pathological sperm forms, plasma membrane integrity (based on the hypoosmotic swelling test results), and acrosome integrity. The highest values were achieved with samples diluted with the STJ+IMB-2 medium. In this group, the following results were obtained: motility – 54,0±0,4%, velocity (VAP) – 91,8±3,4%, VSL – 75,5±3,9%, VCL – 132,0±3,8%, percentage of anomalies – 16,75%, acrosome integrity – 24,15±0,31%, and plasma membrane integrity was 65,6±0.7%. The obtained data suggest that the STJ+IMB-2 medium provided the most effective protection for sperm during cryopreservation compared to other media such as GTJ and STJ+MP. These results highlight the importance of selecting an appropriate medium to optimize cryopreservation processes and improve fertilization rates. en_US
dc.language.iso en en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject rams en_US
dc.subject sperm en_US
dc.subject ejaculate en_US
dc.subject motility en_US
dc.subject acrosome en_US
dc.subject plasma membrane en_US
dc.title Comparative analysis of cryopreserved ram sperm parameters depending on the dilution medium en_US
dc.title.alternative Сравнителен анализ на параметрите на криоконсервирана сперма от коч в зависимост от използваната среда en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account