Abstract:
This paper is dedicated to increasing the reliability level of bearing type joints refurbished with polymer matrix composites and reinforced with hollow glass microspheres. It was shown experimentally that the reinforcement of examined composite materials with hollow glass microspheres by up to 30% practically did not affect the adhesion and stability of carbon steel substrates while helping to increase the hardness layer of MCP.