  • BANU, S.; BOTNARIUC, V.; GORCEAC, L.; COVAL, A.; CINIC, B.; CHETRUŞ, P.; RAEVSCHI, S. (Tehnica UTM, 2013)
    The objective of this paper is establishing of the optimum conditions for CdS layers deposition by pulverization method on glass substrates coated with a previously deposited tampon SnO2 layer, studies of their electrical ...
  • ROZORYNOV, G.N.; AYMEN, Fendri Mohamed (Tehnica UTM, 2013)
    The basic requirements, produced to the electrostimulation apparatus, are considered. The economical mode of excitation of structures is determined during the leadthrough of electrostimulation. It is shown that it is ...
  • CORCIOVĂ, Călin; ZAHARIA, Dan (Tehnica UTM, 2013)
    Medical equipment quality assurance is part of an overall medical equipment management program for a healthcare facility or system. A complete program includes corrective maintenance or repair, equipment control, asset ...
  • LUPAN, Oleg; CREŢU, Vasilii; TROFIM, Viorel; SONTEA, Victor; PAUPORTÉ, Thierry; CHOW, Lee (Technical University of Moldova, 2013)
    Metal oxides such as zinc oxide have been studied intensively as H2 sensors during of the last decade. Zn1-xCdxO is a material which presents new properties at nanometer dimensions. This work demonstrates an enhanced ...
  • DANILOV, Lucian (Tehnica UTM, 2013)
    Background: Considering the role of palatal tonsils in the human body, medical professionals exercise cautiousness when considering tonsillectomy, especially in children, when the tonsil’s physiological function is at ...
  • SPINEI, Aurelia; NICA, Iurie (Tehnica UTM, 2013)
    A device for treatment various infectious diseases was developed. The device performed process of treating infected cavities. We present results of investigations of the influence of ultraviolet radiations over the bacterial ...
  • TSIULYANU, D.; MOCREAC, O.; ENACHI, M.; VOLODINA, G. (Technical University of Moldova, 2013)
    The extinction of sensitivity to nitrogen dioxide induced by high gas concentration have been observed in ultrathin tellurium films. The phenomenon becomes apparent in both continuous and nanostructured films shown by AFM, ...
  • USHENKO, V.O.; KOVAL, G.D.; DUBOLAZOV, A.V.; KARACHEVTSEV, A. O.; OLAR, O. I.; BOYCHUK, T. M. (Tehnica UTM, 2013)
    The optical model of polycrystalline networks of myometium is suggested. The results of investigating the interrelation between the values correlation (correlation area, asymmetry coefficient and autocorrelation function ...
  • VASILIEVA, O. (Tehnica UTM, 2013)
    The dynamics of an exciton–polariton parametric oscillator has been investigated. A system of nonlinear differential equations has been obtained for describing the time evolution of the densities of pump and signal polaritons. ...
  • NACU, Victoria; TRIFAN, Victoria; LÎSÎI, Cornel; COROBCIUC, Alexei; BITCA, Angela; NACU, Viorel; DUMITRU, Vartic; NACU, Viorel (Tehnica UTM, 2013)
    Background: Type 1 diabetes is a multisystem disease with both biochemical and anatomical consequences. It is a chronic disease of carbohydrate, fat and protein metabolism caused by the lack of insulin, resulting in ...
  • LUPAN, Oleg; CREŢU, Vasilii; RAILEAN, Serghei (Technical University of Moldova, 2013)
    Single-crystal tin oxide (SnO2) nanostructures with rutile structure have been synthesized through a facile hydrothermal process. The morphologies and structural properties of the nanorods/nanoneedles/nanowires were ...
  • CULEAC, I.; NISTOR, I.; IOVU, M.; BUZDUGAN, A.; CIORNEA, V.; COJOCARU, I. (Tehnica UTM, 2013)
    The fiber optic intrusion monitoring system comprises a multimode optical fiber connected to a coherent light source, a CCD detector and a processor for generation of the output signal. The system is based on the principle ...
  • GERNGROSS, M.-D.; HRKAC, V.; KIENLE, L.; CARSTENSEN, J.; FÖLL, H. (Tehnica UTM, 2013)
    In this work the galvanic formation of Ni crystallites and Ni nanowires with very high aspect ratios (>1000:1) in porous InP is presented. By depositing a dielectric interlayer on the InP pore walls it is possible to produce ...
  • USHENKO, YU.; ANGELSKY, P.; DUBOLAZOV, A.; KUSHNERICK, L.; BODNAR, L. (Tehnica UTM, 2013)
    The optical model of polycrystalline networks of histological sections of rectum wall is suggested. The results of investigating the interrelation between the values of statistical (statistical moments of the 1st-4th order) ...
  • BREAHNĂ, Radu; TURTUREANU, Irina; LOZOVANU, Svetlana; OJOG, Victor; GANENCO, Andrei; ARNAUT, Oleg (Tehnica UTM, 2013)
    This paper is focused on Functional Electrical Stimulation, a technique that uses electrical stimuli to reestablish the normal activity of organs deprived of nervous control. The concept itself is described along with ...
  • YASHIN, K.D.; DICK, S.K.; ZHAVNERKO, G.K.; OSIPOVICH, V.S.; TERPINSKAYA, T.I.; BARUN, V. V.; KVASYUK, A. A.; PETROVA, E. A. (Tehnica UTM, 2013)
    Core size of the core and the nature of semiconductor CdSe/ZnS nanoparticles (NP’s) were the subject of the research to understand main reasons of the dynamics of “living cell/nanoparticle” interactions. Core size of NP ...
  • BELOUSSOV, Igor (Tehnica UTM, 2013)
    A generalized bipolariton model is proposed. Bipolaritons is formed from virtual excitons of four kinds. There exists both attractive and repulsive interaction between these excitons, though only excitons of a specific ...
  • SONTEA, V.; WERLEIN, R.; ZAUGG, C. (Technical University of Moldova, 2013)
    Maintenance, control and management of medical devices became a priority in a health policy in many countries. Many studies proved that using coherent policies in these areas can improve the cost/efficiency use of advanced ...
  • LAZAR, D.; CIMPOIES, I.; SOROKIN, Gh.; GRITCOV, S. (Technical University of Moldova, 2013)
    This thesis deals with the study of methods of images compression / decompression that require less hardware and time resources, compared to the classical methods. The results of the implementation of these image processing ...
  • MORKVENAITE-VILKONCIENE, Inga; RAMANAVICIUS, Arunas (Tehnica UTM, 2013)
    Scanning Electrochemical Microscopy is a tool for imaging and investigate surfaces by meaning of chemical reactivity, electric conductivity, and enzymatic activity. This technique is typical electrochemical cell plus three ...