IRTUM – Institutional Repository of the Technical University of Moldova

Study on Ferroelectric Thin Film Capacitor for AC-coupled CdTe X-ray Detector

Show simple item record

dc.contributor.author HAYAKAWA, M.
dc.contributor.author NAKAGAWA, H.
dc.contributor.author SAKAIDA, K.
dc.contributor.author AOKI, T.
dc.date.accessioned 2020-05-31T09:46:38Z
dc.date.available 2020-05-31T09:46:38Z
dc.date.issued 2019
dc.identifier.citation HAYAKAWA, M., NAKAGAWA, H., SAKAIDA, K. et al. Study on Ferroelectric Thin Film Capacitor for AC-coupled CdTe X-ray Detector. In: ICNMBE: International conference on Nanotechnologies and Biomedical Engineering: proc. of the 4rd intern. conf., Sept. 18-21 : Program & Abstract Book , 2019. Chişinău, 2019, p. 158. ISBN 978-9975-72-392-3. en_US
dc.identifier.isbn 978-9975-72-392-3
dc.identifier.uri https://doi.org/10.1007/978-3-030-31866-6_131
dc.identifier.uri http://repository.utm.md/handle/5014/8501
dc.description Access full text - https://doi.org/10.1007/978-3-030-31866-6_131 en_US
dc.description.abstract We present that fabricating ferroelectric thin film capacitor on electrodes of the X-ray detector to make AC-coupled CdTe X-ray imager. In order to determine the capacitance required for the coupling capacitor, radiation spectrum is measured by using some coupling capacitor have different capacitance. As a result, it was found that the more the capacitance is large, we can get correct radiation spectrum. Because small capacitor with large capacitance is required, BaTiO3 is selected as a high dielectric constant material. We fabricated a ferroelectric thin film capacitor with an area of about 48 μm2 and a thickness of about 100nm by sputtering. As a result of measurement, the capacitance is about 880 pF, and the tendency of variation of dielectric constant with frequency corresponded with past paper. Although the dielectric constant was significantly smaller than the BaTiO3 film in the papers. We considered that the main issue is quality of BaTiO3 film. Quality of film is increased by depositing under high substrate temperature. Performance of CdTe as a radiation detector is deteriorated by high temperature. Therefore, we need to consider the way to deposit BaTiO3 on CdTe at low substrate temperature. en_US
dc.language.iso en en_US
dc.publisher Tehnica UTM en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject AC-coupling en_US
dc.subject X-ray detectors en_US
dc.subject sputtering en_US
dc.title Study on Ferroelectric Thin Film Capacitor for AC-coupled CdTe X-ray Detector en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account