Elaborarea instalaţiei frigorifice automatizate cu consum redus de energie electrică pentru răcirea laptelui

Show simple item record

dc.contributor.author DAICU, Anatolie
dc.contributor.author SCRIPNIC, Elena
dc.contributor.author VOLCONOVICI, Augustin
dc.contributor.author CHIRSANOVA, Alla
dc.contributor.author VOLCONOVICI, Onorin
dc.contributor.author SLIPENCHI, Victorin
dc.contributor.author VOLCONOVICI, Ina
dc.date.accessioned 2023-05-30T09:00:53Z
dc.date.available 2023-05-30T09:00:53Z
dc.date.issued 2020
dc.identifier.citation DAICU, Anatolie, SCRIPNIC, Elena, VOLCONOVICI, Augustin et al. Elaborarea instalaţiei frigorifice automatizate cu consum redus de energie electrică pentru răcirea laptelui. In: Ştiinţa Agricolă, 2020, nr. 1, pp. 107-114. ISSN 1857-0003. eISSN 2587-3202. en_US
dc.identifier.issn 1857-0003
dc.identifier.issn 2587-3202
dc.identifier.uri http://repository.utm.md/handle/5014/22863
dc.description.abstract Scopul studiului este de a determina perioada optimă și eficiența utilizării instalației automatizate cu consum redus de energie electrică pentru răcirea laptelui cu utilizarea frigului natural. S-a argumentat din punct de vedere a economiei de energie electrică utilizarea instalației cu frig natural în perioada rece a anului și a instalației combinate (instalația frigorifică și instalația cu frig natural) în perioada caldă a anului. Consumul specific de energie electrică pentru răcirea laptelui cu aplicarea frigului natural constituie 0,3 kW h/t în perioada rece a anului, față de 30-35 kW h/t la utilizarea instalațiilor frigorifice tipice. Din analiza temperaturilor înregistrate în zona centrală a Republicii Moldova s-a constatat, că instalația cu frig natural ar putea fi utilizată pentru răcirea laptelui inclusiv și în lunile octombrie şi aprilie, durata de răcire a apei în acumulatorul de frig constituind câteva ore (de la 4 până la 13 ore pentru t ≤ 40 С). en_US
dc.description.abstract The aim of the study has been to determine the optimum period and the efficiency of the use of the automated installation with low energy consumption for milk cooling using natural cold. The use of the natural cooling installation in the cold season and of the combined installation (refrigeration installation and natural cooling installation) in the warm season was substantiated from the point of view of energy saving. The specific consumption of electrical energy for milk cooling by using natural cold constitutes 0,3 kW h/t in the cold season against 30-35 kW h/t when using typical refrigeration installations. From the analysis of temperatures registered in the central zone of the Republic of Moldova, it was established that the natural cooling installation might be used for milk cooling, including in the months of October and April, the duration of water cooling in the cold accumulator constituting several hours (from 4 to 13 hours for t ≤ 40 С).
dc.language.iso ro en_US
dc.publisher Universitatea Agrară de Stat din Moldova en_US
dc.relation.ispartofseries Știința Agricolă;2020, N. 1
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject consum de energie en_US
dc.subject frig natural en_US
dc.subject răcirea laptelui en_US
dc.subject temperatură atmosferică en_US
dc.subject atmospheric temperature en_US
dc.subject energy consumption en_US
dc.subject milk cooling en_US
dc.subject refrigeration equipment en_US
dc.title Elaborarea instalaţiei frigorifice automatizate cu consum redus de energie electrică pentru răcirea laptelui en_US
dc.title.alternative Development of an automated low energy consumption installation for milk cooling en_US