Controlul calităţii echipamentului de brahiterapie la Institutul Oncologic din Moldova

Show simple item record

dc.contributor.advisor BUZDUGAN, Artur
dc.contributor.author CORDUN, Octavian
dc.date.accessioned 2025-02-28T11:48:21Z
dc.date.available 2025-02-28T11:48:21Z
dc.date.issued 2025
dc.identifier.citation CORDUN, Octavian. Controlul calităţii echipamentului de brahiterapie la Institutul Oncologic din Moldova. Teză de master. Programul de studiu Inginerie Biomedicală. Conducător ştiinţific BUZDUGAN Artur. Universitatea Tehnică a Moldovei. Chișinău, 2024. en_US
dc.identifier.uri https://repository.utm.md/handle/5014/30012
dc.description Fişierul ataşat conţine: Rezumat, Annotation, Cuprins, Introducere, Bibliografie. en_US
dc.description.abstract Scopul lucrării este elaborarea și implementarea în Institutul Oncologic a procedurii de control al calității în lucrul cu noul echipamentului de brahiterapie BRAVOS. Obiectivele generale sunt: studiul literaturii pe tema tezei, verificarea periodică a calibrării echipamentului pentru a asigura precizia dozei de radiație, monitorizarea continuă a performanței echipamentului și a rezultatelor clinice pentru a detecta și corecta eventualele abateri, asigurarea respectării reglementărilor internaționale în domeniul radioterapiei, pentru protejarea atât a pacienților, cât și a personalului medical. Domeniul de cercetare se bazează pe implementarea noului program de control al calității în cadrul introducerii noilor tehnologii de tratament 3D în brahiterapie HDR la IMSP Institutul Oncologic. Originalitate științifică constă în elaborarea și implementarea procedurii operaționale de control al calității al sistemului BRAVOS pentru afterloading în incinta IMSP Institutul Oncologic. Teza cuprinde în sine introducere, trei capitole, concluzii și bibliografia. Capitolul 1 pune accentul pe normele de radioprotecție în conformitate cu reglementările de nivel național și internațional din domeniul radioterapiei. De asemenea, include principalele aspecte ale controlului calității în brahiterapie. Capitolul 2 descrie în detaliu componentele sistemului BRAVOS pentru afterloading, alături de procedurile de: verificare a poziției cablului sursei și efectuarea calibrării poziției. Capitolul 3 include caracteristicile de bază ale unei proceduri operaționale. Urmat apoi de elaborarea recomandărilor pentru procedura operațională, în care este descris fiecare secțiune în parte. În cele din urmă, sunt analizate rezultatele obținute pe parcursul anului 2024. În concluzie, se menționeză, că scopul tezei de master a fost realizat cu succes. Rezultatele obținute de la implementarea controlul calității odată cu introducerea sistemul BRAVOS pentru afterloading pe durata anului 2024 au demonstrat eficiența programului de control al calității și justificându-i necesitatea. en_US
dc.description.abstract The purpose of the work is to develop and implement in the Oncology Institute the quality control procedure for working with the new BRAVOS brachytherapy equipment. The general objectives are: study of the literature on the topic of the thesis, periodic verification of equipment calibration to ensure the accuracy of the radiation dose, continuous monitoring of equipment performance and clinical results to detect and correct any deviations, ensuring compliance with international regulations in the field of radiotherapy, to protect both patients and medical personnel. The research field is based on the implementation of the new quality control program within the introduction of new 3D treatment technologies in HDR brachytherapy in IMSP Oncological Institute. Scientific originality consists in the development and implementation of the operational procedure for quality control of the BRAVOS system for afterloading within the premises of the IMSP Oncologic Institute. The thesis includes an introduction, three chapters, conclusions and the bibliography. Chapter one focuses on radiation protection standards in accordance with national and international radiotherapy regulations. It also includes the main aspects of quality control in brachytherapy. The second chapter describes in detail the basic components of the BRAVOS afterloading system, along with the procedures for: verifying the position of the source cable and performing position calibration. The third chapter includes the basic features of an operational procedure. This is followed by the development of recommendations for the operational procedure, in which each section is described separately. Finally, the results obtained during 2024 are analyzed. In conclusion, it is noted that the purpose of the master's thesis was successfully achieved. The results obtained from the implementation of quality control with the introduction of the BRAVOS system for afterloading during 2024 demonstrated the efficiency of the quality control program and justified its need. en_US
dc.language.iso ro en_US
dc.publisher Universitatea Tehnică a Moldovei en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject control al calității en_US
dc.subject brahiterapie HDR en_US
dc.subject BRAVOS en_US
dc.subject quality control en_US
dc.subject HDR brachytherapy en_US
dc.subject Ir-192 en_US
dc.title Controlul calităţii echipamentului de brahiterapie la Institutul Oncologic din Moldova en_US
dc.title.alternative Quality control of brachytherapy equipment at the Oncological Institute of Moldova en_US
dc.type Thesis en_US